8-7-vypolnyaetsya-s-pomoshhyu-universalnogo-pribora-izmerenie-soprotivleniya.html
8.7. It is carried out by means of the universal device – resistance measurement on the ignition coilMeasurement assumes appropriate functioning of a control system by the engine. By means of the universal device in systems of ignition of a high voltage it is possible to check up also primary resistance in a verification mode (resistance W).
|
Switch off ignition.
Disconnect a wire of ignition from the ignition module.
Check of primary resistance:
Disconnect the multicontact tip.
Consistently connect an ohmmeter to plugs 1 and 2, and also 3 and 2. Demanded value: 0,4 – 0,6 W.
|
Conclusions of a multicontact socket. |
|
|
|
|