The reason
|
Elimination
|
A.Kontrolnaja a lamp of indexes of turn is lighted on short intervals, the emergency light alarm system works in a normal rhythm.
|
Defect in indexes of turn or weak contacts. |
Replace – eliminate weak contacts to the help contact aerosols. |
With B.Ukazateli of turn and a control lamp burn not in one rhythm.
|
Defect in the relay of indexes of turn. |
Replace. |
V.Ukazateli of turn is perfectly in order – the emergency light alarm system does not work.
|
Defective safety lock.
Breakage in a wire from plug contact of the switch of the emergency light alarm system to a safety lock or the relay of indexes of turn.
Defect in the switch of the emergency light alarm system.
|
Replace.
Check up passage of a current and if necessary result in serviceability.
Replace.
|
G.Ukazateli of turn does not work – the emergency light alarm system as it should be.
|
Breakage in a wire between the switch of indexes of turn and the relay of indexes of turn. |
Check up passage of a current and if necessary result in serviceability. |