15.10. Check of the door contact switchDoor contact switches for internal illumination take places in door clamps of average and back racks. At occurrence of failures in their functioning check up the switch.
|
Check up by means of a control lamp or a multimeter pressure on door contact switches.
If pressure is not enclosed to them, check up in the beginning a safety lock.
If the safety lock is perfectly in order, check up, beginning from the block of the safety locks, the wires laid to a door.
Probably, «on road» will be found out breakage of a wire or free штекерный contact. Check up also the switch – often contacts can be clamped or корродирован a wire conclusion.
Eliminate defect and then do not forget all switch with effort to move on sliding surfaces there-here and to grease with silicone oil.
If the switch is strongly clamped, clean sliding surfaces gasoline for washing and slightly grease contacts.
If also it does not lead to success replace the defective switch.
|